Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-31613)

high Tenable OT Security Plugin ID 506456

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

smb: client: fix OOB reads parsing symlink error response

When a CREATE returns STATUS_STOPPED_ON_SYMLINK, smb2_check_message() returns success without any length validation, leaving the symlink parsers as the only defense against an untrusted server.

symlink_data() walks SMB 3.1.1 error contexts with the loop test 'p < end', but reads p->ErrorId at offset 4 and p->ErrorDataLength at offset 0. When the server-controlled ErrorDataLength advances p to within 1-7 bytes of end, the next iteration will read past it. When the matching context is found, sym->SymLinkErrorTag is read at offset 4 from p->ErrorContextData with no check that the symlink header itself fits.

smb2_parse_symlink_response() then bounds-checks the substitute name using SMB2_SYMLINK_STRUCT_SIZE as the offset of PathBuffer from iov_base. That value is computed as sizeof(smb2_err_rsp) + sizeof(smb2_symlink_err_rsp), which is correct only when ErrorContextCount == 0.

With at least one error context the symlink data sits 8 bytes deeper, and each skipped non-matching context shifts it further by 8 + ALIGN(ErrorDataLength, 8). The check is too short, allowing the substitute name read to run past iov_len. The out-of-bound heap bytes are UTF-16-decoded into the symlink target and returned to userspace via readlink(2).

Fix this all up by making the loops test require the full context header to fit, rejecting sym if its header runs past end, and bound the substitute name against the actual position of sym->PathBuffer rather than a fixed offset.

Because sub_offs and sub_len are 16bits, the pointer math will not overflow here with the new greater-than.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506456

File Name: tenable_ot_siemens_CVE-2026-31613.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: High

Score: 7

Percentile: 98.3

CVSS v3

Risk Factor: High

Base Score: 8.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-31613

CWE: 20