Siemens SIMATIC S7-1500 TM MFP Detection of Error Condition Without Action (CVE-2026-23317)

high Tenable OT Security Plugin ID 506443

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

drm/vmwgfx: Return the correct value in vmw_translate_ptr functions

Before the referenced fixes these functions used a lookup function that returned a pointer. This was changed to another lookup function that returned an error code with the pointer becoming an out parameter.

The error path when the lookup failed was not changed to reflect this change and the code continued to return the PTR_ERR of the now uninitialized pointer. This could cause the vmw_translate_ptr functions to return success when they actually failed causing further uninitialized and OOB accesses.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506443

File Name: tenable_ot_siemens_CVE-2026-23317.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.9

Percentile: 97.01

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-23317

CWE: 390