Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-52947)

high Tenable OT Security Plugin ID 506435

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

net: qrtr: fix refcount saturation and potential UAF in qrtr_port_remove

In qrtr_port_remove(), the socket reference count is decremented via
__sock_put() before the port is removed from the qrtr_ports XArray and before the RCU grace period elapses.

This breaks the fundamental RCU update paradigm. It exposes a race window where a concurrent RCU reader (such as qrtr_reset_ports() or qrtr_port_lookup()) can obtain a pointer to the socket from the XArray, and attempt to call sock_hold() on a socket whose reference count has already dropped to zero.

This exact race condition was hit during syzkaller fuzzing, leading to the following refcount saturation warning and a potential Use-After-Free:

refcount_t: saturated; leaking memory.
WARNING: CPU: 3 PID: 1273 at lib/refcount.c:22 refcount_warn_saturate+0xae/0x1d0 Modules linked in: qrtr(+) bochs drm_shmem_helper ...
Call Trace:
<TASK> qrtr_reset_ports net/qrtr/af_qrtr.c:768 [inline] [qrtr]
__qrtr_bind.isra.0+0x48b/0x570 net/qrtr/af_qrtr.c:805 [qrtr] qrtr_bind+0x17d/0x210 net/qrtr/af_qrtr.c:901 [qrtr] kernel_bind+0xe4/0x120 net/socket.c:3592 qrtr_ns_init+0x1a6/0x380 net/qrtr/ns.c:715 [qrtr] qrtr_proto_init+0x3b/0xff0 net/qrtr/af_qrtr.c:169 [qrtr] do_one_initcall+0xf5/0x5e0 init/main.c:1283 ...
</TASK>

Fix this by deferring the reference count decrement until after the xa_erase() and the synchronize_rcu() complete.

(Note: The v1 of this patch incorrectly replaced __sock_put() with sock_put(). As Simon Horman pointed out, the callers of qrtr_port_remove() still hold a reference to the socket, so freeing the socket memory here would lead to a subsequent UAF in the caller. Thus, the __sock_put() is kept, but only repositioned to close the RCU race.)

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506435

File Name: tenable_ot_siemens_CVE-2026-52947.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.9

Percentile: 58.17

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-52947

CWE: 20