Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-52917)

high Tenable OT Security Plugin ID 506392

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

sctp: diag: reject stale associations in dump_one path

The SCTP exact sock_diag lookup can hold a transport reference, block on lock_sock(sk), and then resume after sctp_association_free() has marked the association dead and freed its bind address list.

When that happens, inet_assoc_attr_size() and inet_diag_msg_sctpasoc_fill() can still dereference association state that is no longer valid for reporting. In particular, inet_diag_msg_sctpasoc_fill() may read an empty bind-address list as a real sctp_sockaddr_entry and trigger an out-of-bounds read from unrelated association memory.

Reject the association after taking the socket lock if it has been reaped or detached from the endpoint, and report the lookup as stale.
This keeps the exact dump-one path from formatting torn association state.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: High

ID: 506392

File Name: tenable_ot_siemens_CVE-2026-52917.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: High

Score: 7

Percentile: 98.06

CVSS v3

Risk Factor: High

Base Score: 7.1

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-52917

CWE: 20