Siemens SIMATIC S7-1500 TM MFP Improper Input Validation (CVE-2026-46185)

critical Tenable OT Security Plugin ID 506391

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:

smb/client: fix out-of-bounds read in symlink_data()

Since smb2_check_message() returns success without length validation for the symlink error response, in symlink_data() it is possible for iov->iov_len to be smaller than sizeof(struct smb2_err_rsp). If the buffer only contains the base SMB2 header (64 bytes), accessing err->ErrorContextCount (at offset 66) or err->ByteCount later in symlink_data() will cause an out-of-bounds read.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-784472.html

Plugin Details

Severity: Critical

ID: 506391

File Name: tenable_ot_siemens_CVE-2026-46185.nasl

Version: 1.1

Type: Remote

Family: Tenable.ot

Published: 10/20/2026

Updated: 10/20/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.3

Percentile: 53.69

CVSS v3

Risk Factor: Critical

Base Score: 9.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/13/2026

Vulnerability Publication Date: 10/13/2026

Reference Information

CVE: CVE-2026-46185

CWE: 20