Siemens APE1808 Improper Neutralization of Special Elements used in an OS Command (CVE-2025-4230)

high Tenable OT Security Plugin ID 505259

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A command injection vulnerability in Palo Alto Networks PAN-OS software enables an authenticated administrator to bypass system restrictions and run arbitrary commands as a root user. To be able to exploit this issue, the user must have access to the PAN-OS CLI.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-513708.html

Plugin Details

Severity: High

ID: 505259

File Name: tenable_ot_siemens_CVE-2025-4230.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 3/23/2026

Updated: 3/24/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v3

Risk Factor: Medium

Base Score: 6.7

Temporal Score: 5.8

Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

CVSS v4

Risk Factor: High

Base Score: 8.4

Threat Score: 5.7

Threat Vector: CVSS:4.0/E:U

Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Vulnerability Information

CPE: cpe:/o:siemens:ruggedcom_ape1808_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-4230

CWE: 78