Siemens SCALANCE and RUGGEDCOM Improper Input Validation (CVE-2023-39810)

high Tenable OT Security Plugin ID 505125

Synopsis

The remote OT asset is affected by a vulnerability.

Description

An issue in the CPIO command of Busybox v1.33.2 allows attackers to execute a directory traversal.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-089022.html

https://support.industry.siemens.com/cs/ww/en/view/109997626/

https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06

Plugin Details

Severity: High

ID: 505125

File Name: tenable_ot_siemens_CVE-2023-39810.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 2/10/2026

Updated: 3/5/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: High

Base Score: 7.2

Temporal Score: 5.3

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2023-39810

CVSS v3

Risk Factor: High

Base Score: 7.8

Temporal Score: 6.8

Vector: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xch328_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xcm328_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3, cpe:/o:siemens:scalance_xr-300_series_firmware, cpe:/o:siemens:scalance_xcm324_firmware:3.3, cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3, cpe:/o:siemens:scalance_xcm332_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 1/28/2026

Vulnerability Publication Date: 8/28/2023

Reference Information

CVE: CVE-2023-39810

CWE: 20