Siemens S7-1500 Use After Free (CVE-2025-39977)

high Tenable OT Security Plugin ID 505089

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
futex: Prevent use-after-free during requeue-PI syzbot managed to trigger the following race: T1 T2 futex_wait_requeue_pi() futex_do_wait() schedule() futex_requeue() futex_proxy_trylock_atomic() futex_requeue_pi_prepare() requeue_pi_wake_futex() futex_requeue_pi_complete() /* preempt */ * timeout/ signal wakes T1 * futex_requeue_pi_wakeup_sync() // Q_REQUEUE_PI_LOCKED futex_hash_put() // back to userland, on stack futex_q is garbage /* back */ wake_up_state(q->task, TASK_NORMAL); In this scenario futex_wait_requeue_pi() is able to leave without using futex_q::lock_ptr for synchronization. This can be prevented by reading futex_q::task before updating the futex_q::requeue_state. A reference on the task_struct is not needed because requeue_pi_wake_futex() is invoked with a spinlock_t held which implies a RCU read section. Even if T1 terminates immediately after, the task_struct will remain valid during T2's wake_up_state().
A READ_ONCE on futex_q::task before futex_requeue_pi_complete() is enough because it ensures that the variable is read before the state is updated. Read futex_q::task before updating the requeue state, use it for the following wakeup.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-082556.html

Plugin Details

Severity: High

ID: 505089

File Name: tenable_ot_siemens_CVE-2025-39977.nasl

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 2/10/2026

Updated: 2/10/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 5.2

CVSS v3

Risk Factor: High

Base Score: 7

Vector: CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-39977

CWE: 416