Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53148)

high Tenable OT Security Plugin ID 504617

Synopsis

The remote OT asset is affected by a vulnerability.

Description

comedi: Flush partial mappings in error case If some remap_pfn_range() calls succeeded before one failed, we still have buffer pages mapped into the userspace page tables when we drop the buffer reference with comedi_buf_map_put(bm). The userspace mappings are only cleaned up later in the mmap error path.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

Plugin Details

Severity: High

ID: 504617

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 11/18/2025

Updated: 11/18/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: High

Base Score: 7

Temporal Score: 6.1

Vector: CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:scalance_xr-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 8/12/2025

Vulnerability Publication Date: 8/12/2025

Reference Information

CVE: CVE-2024-53148

CWE: 20