Siemens RUGGEDCOM ROX II Client-Side Enforcement of Server-Side Security (CVE-2025-32469)

critical Tenable OT Security Plugin ID 504451

Synopsis

The remote OT asset is affected by a vulnerability.

Description

The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V2.16.5 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-301229 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-301229.html

https://support.industry.siemens.com/cs/ww/en/view/109988071/

https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-17

Plugin Details

Severity: Critical

ID: 504451

File Name: tenable_ot_siemens_CVE-2025-32469.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 11/18/2025

Updated: 2/14/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: High

Score: 7.3

CVSS v3

Risk Factor: Critical

Base Score: 9.9

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:ruggedcom_rox_rx1400_firmware, cpe:/o:siemens:ruggedcom_rox_rx5000_firmware, cpe:/o:siemens:ruggedcom_rox_rx1501_firmware, cpe:/o:siemens:ruggedcom_rox_rx1500_firmware, cpe:/o:siemens:ruggedcom_rox_rx1512_firmware, cpe:/o:siemens:ruggedcom_rox_mx5000_firmware, cpe:/o:siemens:ruggedcom_rox_mx5000re_firmware, cpe:/o:siemens:ruggedcom_rox_rx1536_firmware, cpe:/o:siemens:ruggedcom_rox_rx1524_firmware, cpe:/o:siemens:ruggedcom_rox_rx1510_firmware, cpe:/o:siemens:ruggedcom_rox_rx1511_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 5/13/2025

Vulnerability Publication Date: 5/13/2025

Reference Information

CVE: CVE-2025-32469

CWE: 602