Siemens SIMATIC S7-1500 Use of a Broken or Risky Cryptographic Algorithm (CVE-2020-13777)

high Tenable OT Security Plugin ID 504035

Synopsis

The remote OT asset is affected by a vulnerability.

Description

GnuTLS 3.6.x before 3.6.14 uses incorrect cryptography for encrypting a session ticket (a loss of confidentiality in TLS 1.2, and an authentication bypass in TLS 1.3). The earliest affected version is 3.6.4 (2018-09-24) because of an error in a 2018-09-18 commit. Until the first key rotation, the TLS server always uses wrong data in place of an encryption key derived from an application.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-398330.html

https://support.industry.siemens.com/cs/ww/en/view/109478459/

Plugin Details

Severity: High

ID: 504035

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 11/13/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 5.2

CVSS v3

Risk Factor: High

Base Score: 7.4

Temporal Score: 6.7

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/12/2023

Vulnerability Publication Date: 12/12/2023

Reference Information

CVE: CVE-2020-13777

CWE: 327