Siemens SIMATIC S7-1500 Buffer Copy without Checking Size of Input (CVE-2023-0687)

medium Tenable OT Security Plugin ID 503980

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability was found in GNU C Library 2.38. It has been declared as critical. This vulnerability affects the function __monstartup of the file gmon.c of the component Call Graph Monitor. The manipulation leads to buffer overflow. It is recommended to apply a patch to fix this issue. VDB-220246 is the identifier assigned to this vulnerability. NOTE: The real existence of this vulnerability is still doubted at the moment. The inputs that induce this vulnerability are basically addresses of the running application that is built with gmon enabled. It's basically trusted input or input that needs an actual security flaw to be compromised or controlled.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0): Only build and run applications from trusted sources.
Currently no fix is available.
- SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0): Only build and run applications from trusted sources.
Currently no fix is available.

Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions prior to V3.1 refer to SiemensSecurity Bulletin SSB-439005.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-398330 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-398330.html

https://support.industry.siemens.com/cs/ww/en/view/109478459/

https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10

Plugin Details

Severity: Medium

ID: 503980

File Name: tenable_ot_siemens_CVE-2023-0687.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 3/5/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 5.9

CVSS v3

Risk Factor: Medium

Base Score: 4.6

Vector: CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/12/2023

Vulnerability Publication Date: 12/12/2023

Reference Information

CVE: CVE-2023-0687

CWE: 120

ICSA: 23-348-10