Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2025-46836)

medium Tenable OT Security Plugin ID 503955

Synopsis

The remote OT asset is affected by a vulnerability.

Description

net-tools is a collection of programs that form the base set of the NET-3 networking distribution for the Linux operating system. Inn versions up to and including 2.10, the Linux network utilities (like ifconfig) from the net-tools package do not properly validate the structure of /proc files when showing interfaces. `get_name()` in `interface.c` copies interface labels from `/proc/net/dev` into a fixed 16-byte stack buffer without bounds checking, leading to possible arbitrary code execution or crash. The known attack path does not require privilege but also does not provide privilege escalation in this scenario. A patch is available and expected to be part of version 2.20.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens is preparing fixed versions and reports that currently, no fix is available.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-082556 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-082556.html

https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-10

https://www.cisa.gov/news-events/ics-advisories/icsa-25-162-05

Plugin Details

Severity: Medium

ID: 503955

File Name: tenable_ot_siemens_CVE-2025-46836.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 11/13/2025

Updated: 2/14/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.7

CVSS v3

Risk Factor: Medium

Base Score: 6.6

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_cpu_firmware:3.1.5, cpe:/o:siemens:siplus_s7-1500_cpu_firmware:3.1.5

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/10/2025

Vulnerability Publication Date: 6/10/2025

Reference Information

CVE: CVE-2025-46836

CWE: 20

ICSA: 23-348-10, 25-162-05