Siemens SIMATIC Devices Stack-based Buffer Overflow (CVE-2021-47107)

high Tenable OT Security Plugin ID 503744

Synopsis

The remote OT asset is affected by a vulnerability.

Description

NFSD: READDIR buffer overflow. If a client sends a READDIR count argument that is too small (say, zero), then the buffer size calculation in the new init_dirlist helper functions results in an underflow, allowing the XDR stream functions to write beyond the actual buffer. This calculation has always been suspect. NFSD has never sanity- checked the READDIR count argument, but the old entry encoders managed the problem correctly. With the commits below, entry encoding changed, exposing the underflow to the pointer arithmetic in xdr_reserve_space(). Modern NFS clients attempt to retrieve as much data as possible for each READDIR request.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: High

ID: 503744

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/30/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: Medium

Base Score: 6.8

Temporal Score: 5.3

Vector: CVSS2#AV:L/AC:L/Au:S/C:C/I:C/A:C

CVSS Score Source: CVE-2021-47107

CVSS v3

Risk Factor: High

Base Score: 7.8

Temporal Score: 7

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 11/8/2022

Reference Information

CVE: CVE-2021-47107

CWE: 121