Siemens SIMATIC Devices Use After Free (CVE-2024-27396)

high Tenable OT Security Plugin ID 503734

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
net: gtp: Fix Use-After-Free in gtp_dellink Since call_rcu, which is called in the hlist_for_each_entry_rcu traversal of gtp_dellink, is not part of the RCU read critical section, it is possible that the RCU grace period will pass during the traversal and the key will be free.
To prevent this, it should be changed to hlist_for_each_entry_safe.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: High

ID: 503734

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-27396

CWE: 416