Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-47706)

medium Tenable OT Security Plugin ID 503711

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
block, bfq: fix possible UAF for bfqq->bic with merge chain In this case, IO from Process 1 will get bfqq2 from BIC1 first, and then get bfqq3 through merge chain, and finially handle IO by bfqq3. Howerver, current code will think bfqq2 is owned by BIC1, like initial state, and set bfqq2->bic to BIC1. Allocated by task 20776:
kasan_save_stack+0x20/0x40 mm/kasan/common.c:45 kasan_set_track+0x25/0x30 mm/kasan/common.c:52
__kasan_slab_alloc+0x87/0x90 mm/kasan/common.c:328 kasan_slab_alloc include/linux/kasan.h:188 [inline] slab_post_alloc_hook mm/slab.h:763 [inline] slab_alloc_node mm/slub.c:3458 [inline] kmem_cache_alloc_node+0x1a4/0x6f0 mm/slub.c:3503 ioc_create_icq block/blk-ioc.c:370 [inline] ---truncated---

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: Medium

ID: 503711

File Name: tenable_ot_siemens_CVE-2024-47706.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:simatic_s7-1500_tm_mfp, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-47706

CWE: 416

ICSA: 25-226-07