Siemens SIMATIC Devices Improper Handling of Structural Elements (CVE-2024-35815)

medium Tenable OT Security Plugin ID 503534

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
fs/aio: Check IOCB_AIO_RW before the struct aio_kiocb conversion The first kiocb_set_cancel_fn() argument may point at a struct kiocb that is not embedded inside struct aio_kiocb. With the current code, depending on the compiler, the req->ki_ctx read happens either before the IOCB_AIO_RW test or after that test. Move the req->ki_ctx read such that it is guaranteed that the IOCB_AIO_RW test happens first.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503534

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-35815

CWE: 237