Siemens SIMATIC Devices Improper Input Validation (CVE-2024-42312)

medium Tenable OT Security Plugin ID 503441

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
sysctl: always initialize i_uid/i_gid Always initialize i_uid/i_gid inside the sysfs core so set_ownership() can safely skip setting them. Commit 5ec27ec735ba (fs/proc/proc_sysctl.c: fix the default values of i_uid/i_gid on /proc/sys inodes.) added defaults for i_uid/i_gid when set_ownership() was not implemented. It also missed adjusting net_ctl_set_ownership() to use the same default values in case the computation of a better value failed.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

Plugin Details

Severity: Medium

ID: 503441

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 10/29/2025

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 4.4

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-1500_tm_mfp

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-42312

CWE: 20