Siemens SIMATIC, SCALANCE and RUGGEDCOM Devices Use After Free (CVE-2024-47696)

high Tenable OT Security Plugin ID 503412

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In the Linux kernel, the following vulnerability has been resolved:
RDMA/iwcm: Fix WARNING:at_kernel/workqueue.c:#check_flush_dependency In the commit aee2424246f9 (RDMA/iwcm: Fix a use-after-free related to destroying CM IDs), the function flush_workqueue is invoked to flush the work queue iwcm_wq. But at that time, the work queue iwcm_wq was created via the function alloc_ordered_workqueue without the flag WQ_MEM_RECLAIM. Because the current process is trying to flush the whole iwcm_wq, if iwcm_wq doesn't have the flag WQ_MEM_RECLAIM, verify that the current process is not reclaiming memory or running on a workqueue which doesn't have the flag WQ_MEM_RECLAIM as that can break forward-progress guarantee leading to a deadlock.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- All affected products: Update to V3.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-355557 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/html/ssa-265688.html

https://cert-portal.siemens.com/productcert/html/ssa-355557.html

https://support.industry.siemens.com/cs/ww/en/view/109988839/

https://www.cisa.gov/news-events/ics-advisories/ICSA-25-226-07

Plugin Details

Severity: High

ID: 503412

File Name: tenable_ot_siemens_CVE-2024-47696.nasl

Version: 1.3

Type: remote

Family: Tenable.ot

Published: 10/27/2025

Updated: 2/12/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: High

Score: 7.4

CVSS v3

Risk Factor: High

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xrh-300_series_firmware, cpe:/o:siemens:scalance_xc-300_series_firmware, cpe:/o:siemens:scalance_xc-400_series_firmware, cpe:/o:siemens:scalance_xch-300_series_firmware, cpe:/o:siemens:scalance_xrm-300_series_firmware, cpe:/o:siemens:scalance_xcm-300_series_firmware, cpe:/o:siemens:scalance_xr-500_series_firmware, cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.2, cpe:/o:siemens:scalance_xr-500wg_series_firmware, cpe:/o:siemens:simatic_s7-1500_tm_mfp, cpe:/o:siemens:scalance_xr-300_series_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/9/2024

Vulnerability Publication Date: 4/9/2024

Reference Information

CVE: CVE-2024-47696

CWE: 416

ICSA: 25-226-07