Siemens SCALANCE W1750D Exposure of Sensitive Information to an Unauthorized Actor (CVE-2023-22791)

medium Tenable OT Security Plugin ID 502162

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability exists in Aruba InstantOS and ArubaOS 10 where an edge-case combination of network configuration, a specific WLAN environment and an attacker already possessing valid user credentials on that WLAN can lead to sensitive information being disclosed via the WLAN. The scenarios in which this disclosure of potentially sensitive information can occur are complex and depend on factors that are beyond the control of the attacker.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has released update V8.10.0.6 for the affected products and recommends users update to the latest version.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- Restrict the command line interface and web-based management interfaces to a dedicated layer 2 segment/VLAN and/or control them by firewall policies at layer 3 and above.
- Block access to port UDP/8211 from untrusted networks.
- Enable cluster-security via the cluster-security command.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-843070 in HTML and CSAF.

See Also

http://www.nessus.org/u?157d0378

https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-02

Plugin Details

Severity: Medium

ID: 502162

File Name: tenable_ot_siemens_CVE-2023-22791.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 3/21/2024

Updated: 2/14/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 4.3

Temporal Score: 3.2

Vector: CVSS2#AV:A/AC:H/Au:S/C:C/I:N/A:N

CVSS Score Source: CVE-2023-22791

CVSS v3

Risk Factor: Medium

Base Score: 4.8

Temporal Score: 4.2

Vector: CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_w1750d_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/10/2023

Vulnerability Publication Date: 10/10/2023

Reference Information

CVE: CVE-2023-22791

ICSA: 23-285-02