Siemens SIMATIC and SIPLUS Products Buffer Access with Incorrect Length Value (CVE-2022-47375)

high Tenable OT Security Plugin ID 501854

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens recommends updating the following products to the latest version where available:

- SINAMICS S120 (incl. SIPLUS variants): Update to V5.2 SP3 HF15 or later version

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- Disable the web server of the affected system
- Restrict access to webserver for trusted users only

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-892915 in HTML and CSAF.

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf

https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-05

Plugin Details

Severity: High

ID: 501854

File Name: tenable_ot_siemens_CVE-2022-47375.nasl

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 1/4/2024

Updated: 2/14/2026

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: High

Base Score: 7.8

Temporal Score: 5.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS Score Source: CVE-2022-47375

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_s7-400_cpu_414f-3_pn%2fdp_firmware, cpe:/o:siemens:siplus_s7-400_cpu_416-3_pn%2fdp_firmware, cpe:/o:siemens:simatic_s7-400_cpu_416f-3_pn%2fdp_firmware, cpe:/o:siemens:siplus_s7-400_cpu_414-3_pn%2fdp_firmware, cpe:/o:siemens:simatic_s7-400_cpu_412-2_pn_firmware, cpe:/o:siemens:simatic_s7-400_cpu_416-3_pn%2fdp_firmware, cpe:/o:siemens:simatic_s7-400_cpu_414-3_pn%2fdp_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 12/12/2023

Vulnerability Publication Date: 12/12/2023

Reference Information

CVE: CVE-2022-47375

CWE: 119, 805