Siemens SCALANCE XCM332 Allocation of Resources Without Limits or Throttling (CVE-2021-46828)

high Tenable OT Security Plugin ID 501084

Synopsis

The remote OT asset is affected by a vulnerability.

Description

In libtirpc before 1.3.3rc1, remote attackers could exhaust the file descriptors of a process that uses libtirpc because idle TCP connections are mishandled. This can, in turn, lead to an svc_run infinite loop without accepting new connections.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens has released an update for the SCALANCE XCM332 and recommends updating to the latest version:

- SCALANCE XCM332 (6GK5332-0GA01-2AC2): Update to V2.2 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security and following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at the Siemens Industrial Security web page.

For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens ProductCERT.

For more information see the associated Siemens security advisory SSA-558014 in HTML and CSAF.

See Also

http://www.nessus.org/u?4af41997

https://cert-portal.siemens.com/productcert/html/ssa-558014.html

http://www.nessus.org/u?990ee1ba

https://www.debian.org/security/2022/dsa-5200

https://lists.debian.org/debian-lts-announce/2022/08/msg00004.html

https://security.netapp.com/advisory/ntap-20221007-0004/

https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-09

https://security.gentoo.org/glsa/202210-33

Plugin Details

Severity: High

ID: 501084

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 5/2/2023

Updated: 7/24/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: High

Base Score: 7.8

Temporal Score: 5.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C

CVSS Score Source: CVE-2021-46828

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_xcm332_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 7/20/2022

Vulnerability Publication Date: 7/20/2022

Reference Information

CVE: CVE-2021-46828

CWE: 770

DSA: DSA-5200

GLSA: GLSA-202210-33