Siemens SINEMA Server < 13 SP2 Unquoted Service Path Local Privilege Escalation (SSA-701708)

This script is Copyright (C) 2016-2017 Tenable Network Security, Inc.


Synopsis :

An application installed on the remote host is affected by a local
privilege escalation vulnerability.

Description :

The version of Siemens SINEMA Server installed on the remote Windows
host is prior to version 13 SP2. It is, therefore, affected by a local
privilege escalation vulnerability due to an unquoted service path. A
local attacker can exploit this, via a malicious executable in the
root path, to elevate privileges.

Note that Nessus has not tested for this issue but has instead relied
only on the application's self-reported version number.

See also :

http://www.nessus.org/u?570c827c
https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02

Solution :

Upgrade to Siemens SINEMA Server version 13 SP2 or later.

Risk factor :

Medium / CVSS Base Score : 6.9
(CVSS2#AV:L/AC:M/Au:N/C:C/I:C/A:C)

Family: SCADA

Nessus Plugin ID: 95714 ()

Bugtraq ID: 94158

CVE ID: CVE-2016-7165