Updated CVEs

IDDescriptionSeverity
CVE-2017-6074The dccp_rcv_state_process function in net/dccp/input.c in the Linux kernel through 4.9.11 mishandles DCCP_PKT_REQUEST packet data structures in the LISTEN state, which allows local users to obtain root privileges or cause a denial of service (double free) via an application that makes an IPV6_RECVPKTINFO setsockopt system call.
high
CVE-2017-6072CMS Made Simple version 1.x Form Builder before version 0.8.1.6 allows remote attackers to conduct information-disclosure attacks via defaultadmin.
medium
CVE-2017-6071CMS Made Simple version 1.x Form Builder before version 0.8.1.6 allows remote attackers to conduct information-disclosure attacks via exportxml.
medium
CVE-2017-6070CMS Made Simple version 1.x Form Builder before version 0.8.1.6 allows remote attackers to execute PHP code via the cntnt01fbrp_forma_form_template parameter in admin_store_form.
critical
CVE-2017-6069Subrion CMS 4.0.5 has CSRF in admin/blog/add/. The attacker can add any tag, and can optionally insert XSS via the tags parameter.
high
CVE-2017-6068Subrion CMS 4.0.5 has CSRF in admin/blocks/add/. The attacker can create any block, and can optionally insert XSS via the content parameter.
high
CVE-2017-6067Symphony 2.6.9 has XSS in publish/notes/edit/##/saved/ via the bottom form field.
medium
CVE-2017-6066Subrion CMS 4.0.5 has CSRF in admin/languages/edit/1/. The attacker can perform any Edit Language action, and can optionally insert XSS via the title parameter.
high
CVE-2017-6065SQL injection vulnerability in inc/lib/Control/Backend/menus.control.php in GeniXCMS through 1.0.2 allows remote authenticated users to execute arbitrary SQL commands via the order parameter.
high
CVE-2017-6062The "OpenID Connect Relying Party and OAuth 2.0 Resource Server" (aka mod_auth_openidc) module before 2.1.5 for the Apache HTTP Server does not skip OIDC_CLAIM_ and OIDCAuthNHeader headers in an "OIDCUnAuthAction pass" configuration, which allows remote attackers to bypass authentication via crafted HTTP traffic.
high
CVE-2017-6061Cross-site scripting (XSS) vulnerability in the help component of SAP BusinessObjects Financial Consolidation 10.0.0.1933 allows remote attackers to inject arbitrary web script or HTML via a GET request. /finance/help/en/frameset.htm is the URI for this component. The vendor response is SAP Security Note 2368106.
medium
CVE-2017-6060Stack-based buffer overflow in jstest_main.c in mujstest in Artifex Software, Inc. MuPDF 1.10a allows remote attackers to have unspecified impact via a crafted image.
high
CVE-2017-6059Mod_auth_openidc.c in the Ping Identity OpenID Connect authentication module for Apache (aka mod_auth_openidc) before 2.14 allows remote attackers to spoof page content via a malicious URL provided to the user, which triggers an invalid request.
high
CVE-2017-6058Buffer overflow in NetRxPkt::ehdr_buf in hw/net/net_rx_pkt.c in QEMU (aka Quick Emulator), when the VLANSTRIP feature is enabled on the vmxnet3 device, allows remote attackers to cause a denial of service (out-of-bounds access and QEMU process crash) via vectors related to VLAN stripping.
high
CVE-2017-6056It was discovered that a programming error in the processing of HTTPS requests in the Apache Tomcat servlet and JSP engine may result in denial of service via an infinite loop. The denial of service is easily achievable as a consequence of backporting a CVE-2016-6816 fix but not backporting the fix for Tomcat bug 57544. Distributions affected by this backporting issue include Debian (before 7.0.56-3+deb8u8 and 8.0.14-1+deb8u7 in jessie) and Ubuntu.
high
CVE-2017-6055XML external entity (XXE) vulnerability in eParakstitajs 3 before 1.3.9 and eParaksts Java lib before 2.5.13 allows remote attackers to read arbitrary files or possibly have unspecified other impact via a crafted edoc file.
high
CVE-2017-6054A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information.
high
CVE-2017-6053A Cross-Site Scripting issue was discovered in Trihedral VTScada Versions prior to 11.2.26. A cross-site scripting vulnerability may allow JavaScript code supplied by the attacker to execute within the user's browser.
medium
CVE-2017-6052A Man-in-the-Middle issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. Communication channel endpoints are not verified, which may allow a remote attacker to access or influence communications between the identified endpoints.
low
CVE-2017-6051An Uncontrolled Search Path Element issue was discovered in BLF-Tech LLC VisualView HMI Version 9.9.14.0 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code.
high
CVE-2017-6050A SQL Injection issue was discovered in Ecava IntegraXor Versions 5.2.1231.0 and prior. The application fails to properly validate user input, which may allow for an unauthenticated attacker to remotely execute arbitrary code in the form of SQL queries.
critical
CVE-2017-6048A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet Solar Datalogger V5.03-1.56a and prior, and SenNet Multitask Meter V5.21a-1.18b and prior. Successful exploitation of this vulnerability could result in the attacker breaking out of the jailed shell and gaining full access to the system.
high
CVE-2017-6046An Insufficiently Protected Credentials issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Sensitive information is insufficiently protected during transmission and vulnerable to sniffing, which could lead to information disclosure.
high
CVE-2017-6045An Information Exposure issue was discovered in Trihedral VTScada Versions prior to 11.2.26. Some files are exposed within the web server application to unauthenticated users. These files may contain sensitive configuration information.
high
CVE-2017-6044An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
critical
CVE-2017-6043A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available.
high
CVE-2017-6042A Cross-Site Request Forgery issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Affected devices do not verify if a request was intentionally sent by the logged-in user, which may allow an attacker to trick a client into making an unintentional request to the web server that will be treated as an authentic request.
high
CVE-2017-6041An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection.
critical
CVE-2017-6040An Information Exposure issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. Non-sensitive information can be obtained anonymously.
medium
CVE-2017-6039A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device.
medium
CVE-2017-6038A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.
high
CVE-2017-6037A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system.
high
CVE-2017-6036A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination.
medium
CVE-2017-6035A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system.
high
CVE-2017-6034An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
critical
CVE-2017-6033A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
high
CVE-2017-6032A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
medium
CVE-2017-6031A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution.
high
CVE-2017-6030A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
medium
CVE-2017-6029A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution.
medium
CVE-2017-6028An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
critical
CVE-2017-6027An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution.
critical
CVE-2017-6026A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
critical
CVE-2017-6025A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code.
critical
CVE-2017-6024A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller.
medium
CVE-2017-6023An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.
critical
CVE-2017-6022A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
critical
CVE-2017-6019An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
high
CVE-2017-6018An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.
medium
CVE-2017-6017A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
high