| 20.13 (L1) Ensure 'Web browser is supported and secured' | CIS Microsoft Windows 10 EMS Gateway v3.0.0 L1 | Windows | CONFIGURATION MANAGEMENT, SYSTEM AND COMMUNICATIONS PROTECTION |
| AIOS-18-015500 - Apple iOS/iPadOS 18 must disable the download of iOS/iPadOS beta updates. | AirWatch - DISA Apple iOS/iPadOS 18 v2r3 | MDM | CONFIGURATION MANAGEMENT |
| GOOG-11-010200 - Google Android 11 must be configured to disallow configuration of date and time. | AirWatch - DISA Google Android 11 COBO v2r1 | MDM | CONFIGURATION MANAGEMENT |
| MSFT-11-010200 - Microsoft Android 11 must be configured to disallow configuration of date and time. | AirWatch - DISA Microsoft Android 11 COPE v1r2 | MDM | CONFIGURATION MANAGEMENT |
| O121-BP-021200 - Access to default accounts used to support replication must be restricted to authorized DBAs. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-BP-022500 - Oracle roles granted using the WITH ADMIN OPTION must not be granted to unauthorized accounts. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-BP-023700 - Application owner accounts must have a dedicated application tablespace. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-BP-024200 - Use of the DBMS installation account must be logged. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-BP-026300 - Remote database or other external access must use fully-qualified names. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-C1-015000 - DBMS default accounts must be assigned custom passwords. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-C1-019700 - The DBMS must employ cryptographic mechanisms preventing the unauthorized disclosure of information during transmission unless the transmitted data is otherwise protected by alternative physical measures. | DISA Oracle Database 12c STIG v3r5 Windows | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O121-C2-001700 - The DBMS must support the disabling of network protocols deemed by the organization to be nonsecure. | DISA Oracle Database 12c STIG v3r5 Windows | Windows | CONFIGURATION MANAGEMENT |
| O121-C2-004900 - The DBMS must verify account lockouts persist until reset by an administrator. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | CONFIGURATION MANAGEMENT |
| O121-C2-006600 - Databases utilizing Discretionary Access Control (DAC) must enforce a policy that limits propagation of access rights. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | ACCESS CONTROL |
| O121-C2-007000 - The DBMS must generate audit records for the DoD-selected list of auditable events, to the extent such information is available. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | AUDIT AND ACCOUNTABILITY |
| O121-C2-007400 - The DBMS must produce audit records containing sufficient information to establish what type of events occurred. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | AUDIT AND ACCOUNTABILITY |
| O121-C2-009300 - The system must protect audit information from any type of unauthorized access. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | AUDIT AND ACCOUNTABILITY |
| O121-C2-013300 - The DBMS must ensure users are authenticated with an individual authenticator prior to using a shared authenticator. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | IDENTIFICATION AND AUTHENTICATION |
| O121-C2-013900 - The DBMS must support organizational requirements to enforce minimum password length. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | IDENTIFICATION AND AUTHENTICATION |
| O121-C2-014000 - The DBMS must support organizational requirements to prohibit password reuse for the organization-defined number of generations. | DISA Oracle Database 12c STIG v3r5 OracleDB | OracleDB | IDENTIFICATION AND AUTHENTICATION |
| O121-C2-016600 - The DBMS must implement required cryptographic protections using cryptographic modules complying with applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance. | DISA Oracle Database 12c STIG v3r5 Windows | Windows | IDENTIFICATION AND AUTHENTICATION |
| O365-CO-000001 - The Macro Runtime Scan Scope must be enabled for all documents. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-CO-000003 - The Office client must be prevented from polling the SharePoint Server for published links. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT, SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-CO-000008 - Office applications must be configured to specify encryption type in password-protected Office 97-2003 files. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-CO-000012 - Office applications must not load XML expansion packs with Smart Documents. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT |
| O365-CO-000017 - The Information Bar must be enabled in all Office programs. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-CO-000018 - The Local Machine Zone Lockdown Security must be enabled in all Office programs. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT |
| O365-CO-000027 - Flash player activation must be disabled in all Office programs. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000007 - Open/save of Excel 2 macrosheets and add-in files must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000010 - Open/save of Excel 3 worksheets must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000021 - AutoRepublish in Excel must be disabled. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT |
| O365-EX-000024 - Scan of encrypted macros in Excel Open XML workbooks must be enabled. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000027 - Macros must be blocked from running in Excel files from the Internet. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000032 - Files from unsafe locations must be opened in Excel in Protected View mode. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-EX-000034 - File attachments from Outlook must be opened in Excel in Protected mode. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-OU-000004 - Scripts associated with shared folders must be prevented from execution in Outlook. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-OU-000015 - The ability to demote attachments from Level 2 to Level 1 must be disabled. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-OU-000026 - When an untrusted program attempts to send e-mail programmatically using the Outlook object model, Outlook must automatically deny it. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-PR-000001 - Trusted Locations on the network must be disabled in Project. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-PT-000002 - The ability to run programs from PowerPoint must be disabled. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-PT-000005 - Encrypted macros in PowerPoint Open XML presentations must be scanned. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-PT-000011 - Files in unsafe locations must be opened in Protected view in PowerPoint. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-VI-000001 - VBA Macros not digitally signed must be blocked in Visio. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT |
| O365-VI-000004 - Visio 2000-2002 Binary Drawings, Templates and Stencils must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-VI-000005 - Visio 2003-2010 Binary Drawings, Templates and Stencils must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-WD-000001 - Word must automatically disable unsigned add-ins without informing users. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | CONFIGURATION MANAGEMENT |
| O365-WD-000005 - If file validation fails, files must be opened in Protected view in Word with ability to edit disabled. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-WD-000006 - Word attachments opened from Outlook must be in Protected View. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-WD-000009 - Open/Save of Word 2000 binary documents and templates must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |
| O365-WD-000013 - Open/Save of Word 95 binary documents and templates must be blocked. | DISA Microsoft Office 365 ProPlus STIG v3r5 | Windows | SYSTEM AND COMMUNICATIONS PROTECTION |