| 2.2.6 - AirWatch - Set Maximum Auto-lock | AirWatch - CIS Apple iOS 9 v1.0.0 L1 | MDM | ACCESS CONTROL |
| 2.3.9.1 Ensure 'Microsoft network server: Amount of idle time required before suspending session' is set to '15 or fewer minute(s)' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 2.3.9.1 Ensure 'Microsoft network server: Amount of idle time required before suspending session' is set to '15 or fewer minute(s)' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 | Windows | ACCESS CONTROL |
| 2.3.9.1 Ensure 'Microsoft network server: Amount of idle time required before suspending session' is set to '15 or fewer minute(s)' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 BL | Windows | ACCESS CONTROL |
| 2.3.9.1 Ensure 'Microsoft network server: Amount of idle time required before suspending session' is set to '15 or fewer minute(s)' | CIS Microsoft Windows 11 Stand-alone v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 2.3.9.1 Ensure 'Microsoft network server: Amount of idle time required before suspending session' is set to '15 or fewer minute(s)' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 3.4.3 Ensure 'Maximum Auto-Lock' is set to '2 minutes' or less | AirWatch - CIS Apple iOS 11 v1.0.0 Institution Owned L1 | MDM | ACCESS CONTROL |
| 4.1.3.2 Ensure 'Prevent enabling lock screen slide show' is set to 'Enabled' | CIS Microsoft Intune for Windows 10 v5.0.0 L1 | Windows | ACCESS CONTROL |
| 4.10.29.5.1 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Intune for Windows 10 v5.0.0 L1 | Windows | ACCESS CONTROL |
| 4.10.29.5.1 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Intune for Windows 11 v5.0.0 L1 | Windows | ACCESS CONTROL |
| 4.10.29.5.2 Ensure 'Require a password when a computer wakes (plugged in)' is set to 'Enabled' | CIS Microsoft Intune for Windows 11 v5.0.0 L1 | Windows | ACCESS CONTROL |
| 4.11.35.4.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Intune for Windows 10 v5.0.0 L2 | Windows | ACCESS CONTROL |
| 4.11.35.4.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Intune for Windows 11 v5.0.0 L2 | Windows | ACCESS CONTROL |
| 18.1.1.1 Ensure 'Prevent enabling lock screen camera' is set to 'Enabled' | CIS Microsoft Windows 11 Stand-alone v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 18.1.1.2 Ensure 'Prevent enabling lock screen slide show' is set to 'Enabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 | Windows | ACCESS CONTROL |
| 18.1.1.2 Ensure 'Prevent enabling lock screen slide show' is set to 'Enabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 BL NG | Windows | ACCESS CONTROL |
| 18.9.28.1 Ensure 'Disallow copying of user input methods to the system account for sign-in' is set to 'Enabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L2 BL | Windows | ACCESS CONTROL |
| 18.9.28.1 Ensure 'Disallow copying of user input methods to the system account for sign-in' is set to 'Enabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L2 | Windows | ACCESS CONTROL |
| 18.9.28.1 Ensure 'Disallow copying of user input methods to the system account for sign-in' is set to 'Enabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L2 | Windows | ACCESS CONTROL |
| 18.9.28.1 Ensure 'Disallow copying of user input methods to the system account for sign-in' is set to 'Enabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L2 BL | Windows | ACCESS CONTROL |
| 18.9.35.6.3 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows Server 2019 v5.0.0 L1 DC | Windows | ACCESS CONTROL |
| 18.9.35.6.3 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows Server 2022 v5.1.0 L1 DC | Windows | ACCESS CONTROL |
| 18.9.35.6.3 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows Server 2025 Stand-alone v2.0.0 L1 MS | Windows | ACCESS CONTROL |
| 18.9.35.6.4 Ensure 'Require a password when a computer wakes (plugged in)' is set to 'Enabled' | CIS Microsoft Windows Server 2022 Stand-alone v2.0.0 L1 MS | Windows | ACCESS CONTROL |
| 18.9.35.6.5 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 | Windows | ACCESS CONTROL |
| 18.9.35.6.5 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 NG | Windows | ACCESS CONTROL |
| 18.9.35.6.5 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 BL | Windows | ACCESS CONTROL |
| 18.9.35.6.5 Ensure 'Require a password when a computer wakes (on battery)' is set to 'Enabled' | CIS Microsoft Windows 11 Stand-alone v5.0.0 L1 | Windows | ACCESS CONTROL |
| 18.9.35.6.6 Ensure 'Require a password when a computer wakes (plugged in)' is set to 'Enabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 | Windows | ACCESS CONTROL |
| 18.9.35.6.6 Ensure 'Require a password when a computer wakes (plugged in)' is set to 'Enabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 NG | Windows | ACCESS CONTROL |
| 18.9.65.2.2 (L1) Ensure 'Do not allow passwords to be saved' is set to 'Enabled' | CIS Azure Compute Microsoft Windows Server 2019 v1.0.0 L1 DC | Windows | ACCESS CONTROL |
| 18.9.65.2.2 (L1) Ensure 'Do not allow passwords to be saved' is set to 'Enabled' | CIS Azure Compute Microsoft Windows Server 2022 v1.0.0 L1 MS | Windows | ACCESS CONTROL |
| 18.9.91.1 (L1) Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Azure Compute Microsoft Windows Server 2019 v1.0.0 L1 DC | Windows | ACCESS CONTROL |
| 18.9.91.1 (L1) Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Azure Compute Microsoft Windows Server 2022 v1.0.0 L1 DC | Windows | ACCESS CONTROL |
| 18.10.57.3.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Windows Server 2022 v5.1.0 L1 MS | Windows | ACCESS CONTROL |
| 18.10.57.3.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 BL NG | Windows | ACCESS CONTROL |
| 18.10.57.3.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 | Windows | ACCESS CONTROL |
| 18.10.57.3.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 BL NG | Windows | ACCESS CONTROL |
| 18.10.57.3.10.1 Ensure 'Set time limit for active but idle Remote Desktop Services sessions' is set to 'Enabled: 15 minutes or less, but not Never (0)' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 NG | Windows | ACCESS CONTROL |
| 18.10.83.1 Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Microsoft Windows Server 2019 v5.0.0 L1 DC | Windows | ACCESS CONTROL |
| 18.10.83.2 Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 BL | Windows | ACCESS CONTROL |
| 18.10.83.2 Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 | Windows | ACCESS CONTROL |
| 18.10.83.2 Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 18.10.83.2 Ensure 'Sign-in and lock last interactive user automatically after a restart' is set to 'Disabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 NG | Windows | ACCESS CONTROL |
| 19.7.8.1 Ensure 'Configure Windows spotlight on lock screen' is set to 'Disabled' | CIS Microsoft Windows 10 Enterprise v5.0.0 L1 BL | Windows | ACCESS CONTROL |
| 19.7.8.1 Ensure 'Configure Windows spotlight on lock screen' is set to 'Disabled' | CIS Microsoft Windows 11 Enterprise v5.1.0 L1 | Windows | ACCESS CONTROL |
| 19.7.8.1 Ensure 'Configure Windows spotlight on lock screen' is set to 'Disabled' | CIS Microsoft Windows Server 2025 v2.1.0 L1 MS | Windows | ACCESS CONTROL |
| 19.7.8.1 Ensure 'Configure Windows spotlight on lock screen' is set to 'Disabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 | Windows | ACCESS CONTROL |
| 19.7.8.1 Ensure 'Configure Windows spotlight on lock screen' is set to 'Disabled' | CIS Microsoft Windows 10 Stand-alone v5.0.0 L1 NG | Windows | ACCESS CONTROL |
| Interactive logon: Smart card removal behavior | MSCT Windows Server 2019 MS v1.0.0 | Windows | ACCESS CONTROL |