Item Search

NameAudit NamePluginCategory
1.1 O365-AC-000001CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

1.66 O365-EX-000034CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

1.71 O365-OU-000003CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

1.99 O365-PR-000003CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

CONFIGURATION MANAGEMENT

1.104 O365-PT-000005CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

1.106 O365-PT-000007CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

1.138 O365-WD-000016CIS Microsoft Office 365 ProPlus STIG v1.1.0 CAT IIWindows

SYSTEM AND COMMUNICATIONS PROTECTION

2.3.27.19 Ensure 'Suppress hyperlink warnings' is set to 'Disabled'CIS Microsoft Office Enterprise v1.2.0 L1Windows

SYSTEM AND INFORMATION INTEGRITY

4.3 Ensure Encryption of Data in Transit TLS or SSL (Transport Encryption)CIS MongoDB 5 v1.2.0 L1 UnixUnix

SYSTEM AND COMMUNICATIONS PROTECTION

4.3 Ensure Encryption of Data in Transit TLS or SSL (Transport Encryption)CIS MongoDB 7 v2.0.0 L1 WindowsWindows

ACCESS CONTROL, IDENTIFICATION AND AUTHENTICATION, SYSTEM AND COMMUNICATIONS PROTECTION

4.3 Ensure Encryption of Data in Transit TLS or SSL (Transport Encryption)CIS MongoDB 8 v2.0.0 L1 UnixUnix

ACCESS CONTROL, IDENTIFICATION AND AUTHENTICATION, SYSTEM AND COMMUNICATIONS PROTECTION

18.9.33.6.1 (L2) Ensure 'Allow network connectivity during connected-standby (on battery)' is set to 'Disabled'CIS Microsoft Windows Server 2016 v4.0.0 L2 DCWindows

CONFIGURATION MANAGEMENT

18.9.35.6.1 Ensure 'Allow network connectivity during connected-standby (on battery)' is set to 'Disabled'CIS Microsoft Windows Server 2025 v2.1.0 L2 MSWindows

CONFIGURATION MANAGEMENT

18.9.35.6.1 Ensure 'Allow network connectivity during connected-standby (on battery)' is set to 'Disabled'CIS Microsoft Windows Server 2019 v5.0.0 L2 DCWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2019 v5.0.0 L2 MSWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2025 v2.1.0 L2 MSWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2019 Stand-alone v4.0.0 L2 MSWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2019 v5.0.0 L2 DCWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2022 v5.1.0 L2 MSWindows

CONFIGURATION MANAGEMENT

18.9.35.6.2 Ensure 'Allow network connectivity during connected-standby (plugged in)' is set to 'Disabled'CIS Microsoft Windows Server 2025 Stand-alone v2.0.0 L2 MSWindows

CONFIGURATION MANAGEMENT

ESXI5-VMNET-000007 - Only authorized administrators must have access to virtual networking components.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

ESXI5-VMNET-000008 - All physical switch ports must be configured with spanning tree disabled.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

ESXI5-VMNET-000015 - The system must ensure the dvPortGroup MAC Address Change policy is set to reject.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

SYSTEM AND COMMUNICATIONS PROTECTION

ESXI5-VMNET-000025 - Spanning tree protocol must be enabled and BPDU guard and Portfast must be disabled on the upstream physical switch port for virtual machines that route or bridge traffic.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

ESXI5-VMNET-000036 - All IP-based storage traffic must be isolated to a management-only network using a dedicated, management-only vSwitch.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

ESXI5-VMNET-000046 - All IP-based storage traffic must be isolated using a vSwitch containing management-only port groups.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN000790-ESXI5-000085 - The system must prevent the use of dictionary words for passwords - V-39418DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN000945-ESXI5-000333 - The root accounts library search path must be the system default and must contain only absolute paths.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN002140-ESXI5-000046 - All shells referenced in /etc/passwd must be listed in the /etc/shells file, except any shells specified for the purpose of preventing logins.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN002400-ESXI5-10047 - The system must be checked weekly for unauthorized setuid files, as well as, unauthorized modification to authorized setuid files.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN003510-ESXI5-006660 - Kernel core dumps must be disabled unless needed.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN005460-ESXI5-000060 - The system must only use remote syslog servers (log hosts) justified and documented using site-defined procedures.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

AUDIT AND ACCOUNTABILITY

GEN005516-ESXI5-703 - The SSH client must be configured to not allow TCP forwarding.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN005519-ESXI5-000102 - The SSH daemon must be configured to not allow X11 forwarding.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN005536-ESXI5-000110 - The SSH daemon must perform strict mode checking of home directory configuration files.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN005570-ESXI5-000115 - The system must be configured with a default gateway for IPv6 if the system uses IPv6, unless the system is a router.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN007840-ESXI5-000119 - The DHCP client must be disabled if not used.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

GEN007841-ESXI5-000120 - Wireless network adapters must be disabled.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

ACCESS CONTROL, SYSTEM AND COMMUNICATIONS PROTECTION

JUEX-NM-000510 - The Juniper EX switches must be configured to use FIPS-validated Keyed-Hash Message Authentication Code (HMAC) to protect the integrity of nonlocal maintenance and diagnostic communications.DISA Juniper EX Series Switches Network Device Management STIG v2r5Juniper

MAINTENANCE

O365-AC-000001 - Macros must be blocked from running in Access files from the Internet.DISA Microsoft Office 365 ProPlus STIG v3r5Windows

SYSTEM AND COMMUNICATIONS PROTECTION

O365-VI-000007 - Macros must be blocked from running in Visio files from the Internet.DISA Microsoft Office 365 ProPlus STIG v3r5Windows

SYSTEM AND COMMUNICATIONS PROTECTION

O365-WD-000016 - In Word, macros must be blocked from running, even if Enable all macros is selected in the Macro Settings section of the Trust Center.DISA Microsoft Office 365 ProPlus STIG v3r5Windows

SYSTEM AND COMMUNICATIONS PROTECTION

SRG-OS-000056-ESXI5 - The system must use time sources local to the enclave.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

SRG-OS-000069-ESXI5 - The system must require that passwords contain at least one uppercase alphabetic character.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

IDENTIFICATION AND AUTHENTICATION

SRG-OS-000078-ESXI5 - The system must require that passwords contain a minimum of 14 characters.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

IDENTIFICATION AND AUTHENTICATION

SRG-OS-000090-ESXI5 - The system must verify the integrity of the installation media before installing ESXi.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

SRG-OS-000095-ESXI5 - Inetd and xinetd must be disabled or removed if no network services utilizing them are enabled.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

SRG-OS-000112-ESXI5 - The SSH daemon must be configured to only use the SSHv2 protocol.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

SRG-OS-000113-ESXI5 - The operating system must use organization-defined replay-resistant authentication mechanisms for network access to non-privileged accounts.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

CONFIGURATION MANAGEMENT

SRG-OS-000120-ESXI5 - The password hashes stored on the system must have been generated using a FIPS 140-2 approved cryptographic hashing algorithm.DISA VMWare ESXi 5.0 Server STIG v2r1VMware

IDENTIFICATION AND AUTHENTICATION