SonicWALL - Flood Protection - TCP - Timeout <= 5 minutes

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

The default time assigned to Access Rules for TCP traffic. If a TCP session is active for a period in excess of this setting, the TCP connection will be cleared by the SonicWALL. The default value is 5 minutes, the minimum value is 1 minute, and the maximum value is 999 minutes.

Note: Setting excessively long connection time-outs will slow the reclamation of stale resources, and in extreme cases could lead to exhaustion of the connection cache.

Solution

Navigate to Firewall Settings->Flood Protection->TCP Settings and check off 'Default TCP Connection Timeout (minutes):'. Set it to a value of 5 or less.

Item Details

Category: SYSTEM AND COMMUNICATIONS PROTECTION

References: 800-53|SC-10

Plugin: SonicWALL

Control ID: d0951ebf630eca939a5b97a9908c34a45433ebce509637316ac29f25a22c0f74