Information
All forms of authentication other than CAC must be disabled. Password authentication can be temporarily re-enabled for emergency access to the local SSO domain accounts but it must be disable as soon as CAC authentication is functional.
NOTE: Nessus has not performed this check. Please review the benchmark to ensure target compliance.
Solution
1. Login to the Platform Services Controller web interface with [email protected] from
https://<FQDN or IP of PSC>/psc
In an embedded deployment the Platform Services Controller host name or IP address is the same as the vCenter Server host name or IP address.
If you specified a different SSO domain during installation, log in as administrator@<mydomain>.
2. Browse to Single Sign-On >> Configuration.
3. Click the 'Smart Card Configuration' tab, click the 'Edit' button next to 'Authentication Configuration'.
4. Check the box next to 'Password and Windows session authentication'. Click 'OK'.
To re-enable password authentication for troubleshooting run the following command from the PSC:
/opt/vmware/bin/sso-config.sh -set_authn_policy -pwdAuthn true -winAuthn false -certAuthn false -securIDAuthn false -t vsphere.local