PHTN-67-000072 - The Photon operating system must generate audit records when successful/unsuccessful logon attempts occur - faillog

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Audit records can be generated from various components within the information system (e.g., module or policy filter).

Satisfies: SRG-OS-000470-GPOS-00214, SRG-OS-000472-GPOS-00217, SRG-OS-000473-GPOS-00218

Solution

Open /etc/audit/rules.d/audit.STIG.rules with a text editor and add the following lines:

-w /var/log/faillog -p wa
-w /var/log/lastlog -p wa
-w /var/log/tallylog -p wa

At the command line, execute the following command:

# /sbin/augenrules --load

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_VMW_vSphere_6-7_Y22M04_STIG.zip

Item Details

References: CAT|II, CCI|CCI-000172, Rule-ID|SV-239143r816646_rule, STIG-ID|PHTN-67-000072, Vuln-ID|V-239143

Plugin: Unix

Control ID: ea1afd1ec22f88b5d4a781930e31a41c14a5a2681ba1c1ee8b0dc4c1be08bdf1