OL09-00-000745 - OL 9 must be configured so that successful/unsuccessful uses of the shutdown command generate an audit record.

Information

Misuse of the shutdown command may cause availability issues for the system.

Solution

Configure the audit system to generate an audit event for any successful/unsuccessful uses of the shutdown command by adding or updating the following rule in the "/etc/audit/rules.d/audit.rules" file:

-a always,exit -F path=/usr/sbin/shutdown -F perm=x -F auid>=1000 -F auid!=unset -k privileged-shutdown

The audit daemon must be restarted for the changes to take effect.

Restart auditd:
$ sudo service auditd restart

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_Linux_9_V1R2_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-12c., CAT|II, CCI|CCI-000172, Rule-ID|SV-271576r1092570_rule, STIG-ID|OL09-00-000745, Vuln-ID|V-271576

Plugin: Unix

Control ID: 5ded09daffe878f1a86aa026522e8cb24572d472ec257faa084f3dcaa3b05ea2