F5BI-DM-300013 - The F5 BIG-IP appliance must be configured to enforce the limit of three consecutive invalid logon attempts, after which time it must block any login attempt for at least 15 minutes.

Information

By limiting the number of failed logon attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute-forcing, is reduced.

NOTE: Nessus has provided the target output to assist in reviewing the benchmark to ensure target compliance.

Solution

From the BIG-IP GUI:
1. System.
2. Users.
3. Authentication.
4. Set Maximum Login Failures to "3".
5. Set User Lockout to "Automatically enable locked-out user after 900 seconds".
6. Update.

From the BIG-IP console, type the following commands:

tmsh modify auth password-policy max-login-failures 3
tmsh modify auth password-policy lockout-duration 900
tmsh save sys config

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_F5_BIG-IP_TMOS_Y25M07_STIG.zip

Item Details

Category: ACCESS CONTROL

References: 800-53|AC-7a., CAT|II, CCI|CCI-000044, Rule-ID|SV-266069r1024600_rule, STIG-ID|F5BI-DM-300013, Vuln-ID|V-266069

Plugin: F5

Control ID: 34d37937b8f0a2374725bf8c8f1f58a1ad3086d89f7a4edb29c228cf3c2f6435