F5BI-DM-300057 - The F5 BIG-IP appliance must set the idle time before automatic logout to five minutes of inactivity except to fulfill documented and validated mission requirements.

Information

Terminating an idle session within a short time period reduces the window of opportunity for unauthorized personnel to take control of a management session enabled on the console or console port that has been left unattended. In addition, quickly terminating an idle session will also free up resources committed by the managed network element.

Terminating network connections associated with communications sessions includes, for example, deallocating associated TCP/IP address/port pairs at the operating system level, or deallocating networking assignments at the application level if multiple application sessions are using a single, operating system-level network connection. This does not mean that the device terminates all sessions or network access; it only ends the inactive session and releases the resources associated with that session.

Satisfies: SRG-APP-000190-NDM-000267, SRG-APP-000003-NDM-000202

Solution

From the BIG-IP GUI:
HTTPD/TMSH:
1. System.
2. Preferences.
3. Under Security Settings configure "Idle Time Before Automatic Logout" to 300 seconds.
4. Click "Update".

SSHD:
1. System.
2. Configuration.
3. Device.
4. SSHD.
5. Configure "Idle Time Before Automatic Logout" to 300 seconds.
6. Click "Update".

From the BIG-IP Console, issue the following commands:
HTTPD/TMSH:
tmsh modify sys httpd auth-pam-idle-timeout 300

tmsh modify sys httpd auth-pam-dashboard-timeout on

tmsh modify sys global-settings console-inactivity-timeout 300

tmsh modify cli global-settings idle-timeout 5

SSHD:
tmsh modify sys sshd inactivity-timeout 300

tmsh save sys config

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_F5_BIG-IP_TMOS_Y25M07_STIG.zip

Item Details

Category: ACCESS CONTROL, SYSTEM AND COMMUNICATIONS PROTECTION

References: 800-53|AC-11a., 800-53|SC-10, CAT|I, CCI|CCI-000057, CCI|CCI-001133, Rule-ID|SV-266095r1024904_rule, STIG-ID|F5BI-DM-300057, Vuln-ID|V-266095

Plugin: F5

Control ID: cdec60a6ca7ce6534ab179681fd89432019d10a97e4d915452a93c0717de91b9