OS10-NDM-000680 - The Dell OS10 Switch must be configured to synchronize internal information system clocks using redundant authoritative time sources.

Information

The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions.

Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must use an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891.

DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be in a different geographic region than the primary time source.

Solution

Configure the OS10 Switch to synchronize internal information system clocks with the primary and secondary time sources:

OS10(config)# ntp authenticate
OS10(config)# ntp trusted-key 345
OS10(config)# ntp authentication-key 345 sha2-256 0 <key>
OS10(config)# ntp server 192.0.2.1 key 345 prefer
OS10(config)# ntp server 192.0.2.5 key 345

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Dell_OS10_Switch_Y24M12_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-8(1), CAT|II, CCI|CCI-004922, CCI|CCI-004923, Rule-ID|SV-270644r1052341_rule, STIG-ID|OS10-NDM-000680, Vuln-ID|V-270644

Plugin: Dell_OS10

Control ID: 9c2c3407bf4a98ba609fa45634d3a7a0a94a27907ab87ab7ce7895f118e5d5dc