JUEX-NM-000460 - The Juniper EX switch must be configured to enforce access restrictions associated with changes to device configuration.

Information

Failure to provide logical access restrictions associated with changes to device configuration may have significant effects on the overall security of the system.

When dealing with access restrictions pertaining to change control, it should be noted that any changes to the hardware, software, and/or firmware components of the device can potentially have significant effects on the overall security of the device.

Accordingly, only qualified and authorized individuals should be allowed to obtain access to device components for the purposes of initiating changes, including upgrades and modifications.

Logical access restrictions include, for example, controls that restrict access to workflow automation, media libraries, abstract layers (e.g., changes implemented into third-party interfaces rather than directly into information systems), and change windows (e.g., changes occur only during specified times, making unauthorized changes easy to discover).

NOTE: Nessus has provided the target output to assist in reviewing the benchmark to ensure target compliance.

Solution

Configure the network device to enforce access restrictions associated with changes to device configuration.

set system login class <name> permissions <permission sets or 'all'>
set system login class <name> deny-commands <appropriate commands to deny>
set system login class <name> deny-configuration-regexps <appropriate configuration hierarchy to deny>

set system login user <account name> class <name>

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Juniper_EX_Switches_Y23M07_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-5(1), CAT|II, CCI|CCI-001813, Rule-ID|SV-253923r879753_rule, STIG-ID|JUEX-NM-000460, Vuln-ID|V-253923

Plugin: Juniper

Control ID: 40e38bfbb2476da4aec97a4f653f4d4b00e02059874ef27bafbbf0efdd307a4f