1.2 UBTU-24-100010

Information

The operating system must not have the "systemd-timesyncd" package installed.

GROUP ID: V-270645
RULE ID: SV-270645r1068357

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Organizations must consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).

Solution

The "systemd-timesyncd" package will be uninstalled as part of the "chrony" package install. The remaining configuration files for "systemd-timesyncd" must be purged from the operating system:

$ sudo apt-get purge systemd-timesyncd

See Also

https://workbench.cisecurity.org/benchmarks/22775

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-6b., CAT|III, CCI|CCI-000366, CSCv7|6.1, Rule-ID|SV-270645r1068357_rule, STIG-ID|UBTU-24-100010, Vuln-ID|V-270645

Plugin: Unix

Control ID: 03416c3d66bc12b79dc3b8768c661c4c1a919aed4c7993f360d77e1dff182306