1.286 OL08-00-030742

Information

OL 8 must disable network management of the chrony daemon.

GROUP ID: V-248822
RULE ID: SV-248822r958478

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Minimizing the exposure of the server functionality of the chrony daemon diminishes the attack surface.

Note that USNO offers authenticated NTP service to DOD and U.S. Government agencies operating on the NIPR and SIPR networks. Visit https://www.usno.navy.mil/USNO/time/ntp/DOD-customers for more information.

Solution

Configure OL 8 to disable network management of the chrony daemon by adding or modifying the following line in the "/etc/chrony.conf" file.

cmdport 0

See Also

https://workbench.cisecurity.org/benchmarks/23791

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-7, 800-53|CM-7a., CAT|III, CCI|CCI-000381, Rule-ID|SV-248822r958478_rule, STIG-ID|OL08-00-030742, Vuln-ID|V-248822

Plugin: Unix

Control ID: 3aca67b7514066dc815aea2d83d50c04b3d7c00440d2b95983cb549bab9a53e9