5.11 DB2CHGPWD_EEE Registry Variable

Information

The DB2CHGPWD_EEE registry variable specifies whether users are able to change passwords through Db2 in a partitioned database environment.

It is recommended to set this variable to NO.

Rationale:

If password management in the partitioned database environment is not centralized, then it could result in a situation where one partition has the updated password for a given user while the rest have the old password which is a security risk.

NOTE: Nessus has provided the target output to assist in reviewing the benchmark to ensure target compliance.

Solution

Run the following command to set the DB2CHGPWD_EEE registry variable to NO:

db2set DB2CHGPWD_EEE=NO

See Also

https://workbench.cisecurity.org/benchmarks/10752

Item Details

Category: ACCESS CONTROL

References: 800-53|AC-2(1), CSCv7|16.2

Plugin: Windows

Control ID: 5e6e86bf76abcbf115036be52d3cf0a36b9004e4383006b9475ec46147be6652