GEN000241 - The system clock must be synchronized continuously.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. Internal system clocks tend to drift and require periodic resynchronization to ensure their accuracy. Software, such as NTPD, can be used to continuously synchronize the system clock with authoritative sources. Alternatively, the system may be synchronized periodically, with a maximum of one day between synchronizations.

If the system is completely isolated (no connections to networks or other systems), time synchronization is not required as no correlation of events or operation of time-dependent protocols between systems will be necessary. If the system is completely isolated, this requirement is not applicable.

Solution

Determine the type of zone that you are currently securing.

# zonename

If the command output is not 'global', then NTP must be disabled.

# svcadm disable ntp

If the output from 'zonename' is 'global', then NTP must be enabled.

# svcadm enable ntp

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_SOL_10_x86_V2R2_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-7, CAT|II, CCI|CCI-000366, CSCv6|9.1, Rule-ID|SV-227561r603266_rule, STIG-ID|GEN000241, STIG-Legacy|SV-26291, STIG-Legacy|V-22290, Vuln-ID|V-227561

Plugin: Unix

Control ID: 8dde9ebc60da214f2fa31323298754874673c06f30f919872876eb4bd0f13cd4