OH12-1X-000001 - OHS must have the mpm property set to use the worker Multi-Processing Module (MPM) as the preferred means to limit the number of allowed simultaneous requests.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Web server management includes the ability to control the number of users and user sessions that utilize a web server. Limiting the number of allowed users and sessions per user is helpful in limiting risks related to several types of Denial of Service attacks.

Although there is some latitude concerning the settings themselves, the settings should follow DoD-recommended values, but the settings should be configurable to allow for future DoD direction. While the DoD will specify recommended values, the values can be adjusted to accommodate the operational requirement of a given system.

Solution

1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/ohs.plugins.nodemanager.properties with an editor.

2. Set the 'mpm' property to a value of 'worker', add the property if it does not exist.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_HTTP_Server_12-1-3_V1R7_STIG.zip

Item Details

Category: ACCESS CONTROL

References: 800-53|AC-10, CAT|II, CCI|CCI-000054, Rule-ID|SV-77643r1_rule, STIG-ID|OH12-1X-000001, Vuln-ID|V-63153

Plugin: Unix

Control ID: d4f35fa866ab354ee3bbd1884e4557fd3a60a178ba3642dd8a79e79f9c991bb2