CISC-ND-001040 - The Cisco switch must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.

Solution

Configure the Cisco switch to record time stamps that meet a granularity of one second as shown in the example below:

SW2(config)#service timestamps log datetime localtime

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Cisco_IOS_Switch_Y21M07_STIG.zip

Item Details

References: CAT|II, CCI|CCI-001889, Rule-ID|SV-220602r521267_rule, STIG-ID|CISC-ND-001040, STIG-Legacy|SV-110433, STIG-Legacy|V-101329, Vuln-ID|V-220602