AMLS-NM-000200 - The Arista Multilayer Switch must generate audit records containing the full-text recording of privileged commands.

Information

Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information.

Organizations consider limiting the additional audit information to only that information explicitly needed for specific audit requirements. The additional information required is dependent on the type of information (i.e., sensitivity of the data and the environment within which it resides). At a minimum, the organization must audit full-text recordings of privileged commands. The organization must maintain audit trails in sufficient detail to reconstruct events to determine the cause and impact of compromise.

Solution

Enable logging on the switch with sufficient detail to fulfill the specifications set forth in the VulDiscussion.

To configure logging to a remote syslog server at the informational level, enter:

switch#config
switch(config)#logging host [ip address]
switch(config)#logging trap informational

Then configure the following AAA:

aaa accounting commands all default start-stop logging [group radius]

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Arista_MLS_DCS-7000_Series_Y20M07_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-3(1), CAT|III, CCI|CCI-000135, Group-ID|V-60851, Rule-ID|SV-75307r1_rule, STIG-ID|AMLS-NM-000200, Vuln-ID|V-60851

Plugin: Arista

Control ID: f51e52c3f4b4be7008a8cb8b0b85f8f1c308625fc290c89ae6d1169f2aeff111