2.4.4 Ensure idle timeout time is configured

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

The idle timeout period is the amount of time that an administrator will stay logged in to the GUI without any activity.

Rationale:

Best practice dictates settings admin idle timeout to prevent the risk of unauthorized access to the device by preventing someone from using a logged-in GUI on a PC that has been left unattended.

Impact:

This is to prevent someone from accessing the FortiGate if the management PC is left unattended.

Solution

To change the idle timeout in the GUI:

1) Login to FortiGate with Super Admin privileges
2) Go to 'System' > 'Settings'.
3) In the 'Administration Settings' section, set the 'Idle timeout' value to five minutes by typing 5.
4) Click Apply.

To change the idle timeout in the CLI:

config system global
set admintimeout 5
end

Default Value:

By default, it is set to five minutes.

See Also